Changing Engine Oil. What does hang up is the PTO safety hookup on the PTO lever itself ( right side of wheel). Though it is a renowned brand, unfortunately, there are some problems you may face. As it is a motor device, having problems from time to time is not uncommon. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. It generally happens if there are any battery issues. The more I read about fuel solenoid the more I think my tractor non-run problem may be related to the fuel solenoid. It is hard to believe that two little wires control the whole contraption. Kubota Tractor won't start. | Tractor Forum To test circuits, fuses and switches use a multimeter tester you can get one here: http://amzn.to/2A5ihXN , you check continuity of circuitssimple example: if you have a standard fuse you put the test wires on either end if fuse is blown it wont show on your meter, if its good needle will go up showing that current can flow through it(Continuity) if your multi-meter doesn't have a dedicated continuity test mode, you can still perform a continuity test. That isn't an issue. Luckily, all these parts are much less money than just one hour of labor. Make sure there is good voltage at the lift pump. For a better experience, please enable JavaScript in your browser before proceeding. Did you run it out of fuel? Removed the solenoid and the tractor started, had to restrict airflow since the fuel solenoid was not connected.. So run the battery voltage test again. If not, try to see a professional who can fix the problem for you. Press J to jump to the feed. L3400 won't start - TractorByNet 1. You must log in or register to reply here. The fuel solenoid is not engaging. Another common problem in Kubota is not getting started at all but just clicking. My tractor is suffering this now, but I do know where to look to get it back running. What happens here is, that every other gear works fine and when you try to use that particular gear. if it is good, in other words it doesnt drop below about 11 volts. If not try the second one. Battery is good. I'm smart and relatively mechanically inclined, but I don't have a lot of experience with diesel or tractors, much less diesel tractors. Thanks, thats what it was, the solenoid wasen't getting power, we worked on it all weekend, some weird relay thing died and isn't sending power to the solenoid. 64. Kansas, Butler county, Just east of DooDah. The ignition lights and dash lights turn on with the key on but the engine does not turn over. Create an account to follow your favorite communities and start taking part in conversations. A battery starts with amps not volts. The dead man switch on my fwd/rev pedal is 100% my culprit for no crank no start. The battery is brand new. Last week i got it out to pull a small tree and did great, put it back under the car port, came back the next day, started right up, drove about 50feet and quit, the engine turns over fine, but won't fire. So run the battery voltage test again. I had it going on Wednesday for about 20 to 30 minutes pushing snow, and then came back a few hours later to do some more work, and it wouldn't start. Any chance a pto is engaged? if its filled with dirt and thick mud-like object, you need to replace the filter. Kubota L3540 Won't Start. It's diesel so it's probably either the injection pump or the lift pump. Try rocking the hydrostatic pedal back and forth, allowing it to return to it's functional position on it's own. Kubota L3400 tractor overview. if it is very low there, then by all means clean/repair the connections. I had two separate things affect starting on mine. As we also learn about what makes them so reliable, and how to properly start and take care of your small. With the key in, turning it to the left does nothing (no lights on dash, etc), Turning the key to start does absolutely nothing, Turning the key to the spot to the right of off, but not all the way to start makes some sort of whining/humming sound like it's trying to do something but it can't. BUT when you said a humming sound, I bet its the battery dropping under load and you are hearing a relay trying to pull in. Press question mark to learn the rest of the keyboard shortcuts. Firstly, check the fuel line. With the wires plugged into each other you have the tractor thinking that the PTO is always disengaged, therefore it will start with the PTO engaged. Still no idea what to do next. Crack a line at an injector and see if you have fuel when cranking the engine. Or if there is any faulty safety switch, it needs to replace too. Why is the steering wheel spinning very easily? Injection pumps rarely fail. Do it for at least fine munities. So, if there is any link of blockage in it, it can also create a problem. Established in 2009, we are the largest online community of Kubota tractor and equipment owners. After some time, this cycle will start all over again. I got the tractor to start and it ran fine. Kubota L3400 starter wont engage. Battery fully charged, - JustAnswer 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. We and our partners use cookies to Store and/or access information on a device. Will it start challenge! Cold weather starting of Kubota equipment Do it again if you feel needed. My relatively new (71 hours) Kubota L3400 will not start. My pantleg occasionally catches the PTO lever on my L3400. Check the Deadman switch under the seat? I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. Or your fuel system needs bleed out so leave the injector line loose and crank for a while. JavaScript is disabled. or the starter engage, you need to know if it is the battery, or high resistance/ connection or something. Standard Transmission. If you have 12V then have someone turn the key on while you listen to see if it starts. First, never use starting fluid in a diesel. If this is HST, rock your forward/reverse pedal back and forth while holding the key in the crank position. The dash lights stay strong and do not dim when the key is turned. So, you need to check the battery first if you are facing this kind of problem. You are using an out of date browser. Kubota is one of the most reliable agricultural vehicles to choose from. Unfortunately, not all tractor is perfect. it should do the work. kubota L3500 cranks but won't start (EDIT) not 3500, L3400, and i think he said it was a 2008 model. Put the solenoid back on and it would start but then die immediately. It should solve the problem. Maybe try jumping the starter just to see if it turns over. Join us in searching for a Kubota diesel that will not start in the cold weather. Kubota L3540 Won't Start : r/kubota - reddit.com Kubota L3400 is a farmers tractor which is a very vital part for some of them. Separating Rear Axle Case from Brake Case, Manual Transmission and Glide Shift Transmission, Double Acting Type 2 (Floating with Detent), Electronic Instrument Panel (Intellipanel), Testing, Setting and Adjusting by Electronic Instrument Panel (Intellipanel), Checking GST Electric Control System (GST Model Only), Air Conditioner Relay, Blower Relays and Compressor Relay, R134A Refrigerant Recovery and Recycling Machine, Air Conditioner System and Front Windshield Wiper10-S31, Disassembling Differential Gear Assembly (L2800), Disassembling Differential Gear Assembly (L3400), Checking High Pressure Relief Valve Pressure, Separating MID Case from Transmission Case, Hydraulic Pump Test Using Flow-Meter (Power Steering), Hydraulic Pump Test Using Flow-Meter (Three Point Hydraulic System), Relief Valve (for Three Point Hydraulic System), Hydraulic Pump (Three Point Hydraulic System), Kubota L3400 Operator's Manual (94 pages), Care of Danger, Warning and Caution Labels, Instrument Panel, Switches and Hand Controls, Foot and Hand Controls (Manual Transmission Type), Warm-Up Transmission Oil in the Low Temperature Range, Do Not Operate the Tractor at Full Speed for the First 50 Hours, hangssig Lubricating Oil for New Tractors, Travel Adjustment/Suspension Adjustment Knob, Head Light/Turn Signal/Hazard Light Switch, Main Gear Shift Lever & Range Gear Shift Lever [Manual Transmission Type], Range Gear Shift Lever (L-M-H) [HST Type], Unlock the Parking Brake and Slowly Release the Clutch, Depress the Speed Control Pedal [HST Type], Make Preparations for Attaching Implement, Hydraulic Control Unit Use Reference Chart, Liquid Weight Per Tire (75 Percent Filled), Cleaning Grill, Radiator Screen and Oil Cooler, Checking Gauges, Meter and Easy Checker (TM), Cleaning Air Cleaner Element [Single Element Type], Replacing Hydraulic Oil Filter/Replacing Transmission Oil Filter [HST Type], Checking HST Oil Line [HST Type]/Checking Power Steering Line, Every 800/1500/3000 Hours and Every 1/2 Year, Flush Cooling System and Changing Coolant, Handling Precautions for Electrical Parts and Wiring. There are 2 coils in there and when the switch is the start position, it puts power to the "pull in coil", when the switch drops into the run position it moves the current to the "hold in coil". We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Open it, start it and let it run for a few minutes then close it. Check if it is dead or have any other problem. Any help would be appreciated. You need a multimeter to start checking voltages. It generally happens when algae grow inside the fuel bowl. 5 Most Common Kubota L3400 Problems (Solutions Included) 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. I thought with a dead battery I would hear clicking, when turning the key. kubota L3500 cranks but won't start : r/tractors - reddit For a better experience, please enable JavaScript in your browser before proceeding. I have a Kubota L3400 with Manual transmission, 4WD. The - JustAnswer Overall, it increases the productivity of the tractor. For almost a Month I could not start the Kubota Tractor, come to find out after testing. Sounds like an obstruction or bad lift pump. Thats usually me. Thanks for the Kubota books site. Or maybe one of the PTOs are engaged? I don't recall the deadman switch working like that, I thought it would only stop the engine if the tractor was moving. You can also do a Biocide treatment and set it for overnight. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. Not the clamp connections, directly on the post's have someone try to start the tractor, anything less than 10.5 or 11 volts indicates either a bad battery (high internal resistance, or sulphated) or a shorted/draggy starter. Got up the next day, no start. 62. Lights can still work with a dead (actually low voltage) battery. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Kubota L3400 died/won't start. I have a lead. Am I right? The other switches to look for are on the clutch pedal, on the range shifter if it is a standard shift or one just above the center of the floor board if it is a hydrostat. The dash lights come on, but when I turn the key all the way there is no click or response at all from the starter. L3200 Won't Start - Help!! | OrangeTractorTalks - Everything Kubota Disconnect the two small wires you will find in the PTO lever. Use an air compressor to flush out if anything is clogged. I tried the solution proposed by crbr, rocking the transmission pedal - and it worked - made my day! Or bad battery connection(s). Checked battery, fuses, fuel and all are good. TONY, DID YOU CHECK THE PTO LEVER, CLUTCH PEDDLE SWITCH AND HIS THE BATTERY CHARGED UP GOOD NO LOOSE CONECTIONS AND SAFETY SWITCH UNDER SEAT. I have a Kubota L3400 with Manual transmission, 4WD. If its still on, check for the cable which runs from the PTO shift and goes into the transmission case under the seat. 63. Closed the air vent cock. Thanks for this threadI was packing up today and this happenednever thought to mess with the pedal until I read this and it started up after a couple of pushes. But since your relays may not even click. 900 to tow it?!? The fuel solenoid shuts off fuel or engages linkage that controls fuel distribution. You must log in or register to reply here. Anyone have any ideas on what to do next? Press question mark to learn the rest of the keyboard shortcuts. Please explain what you mean by 'won't start': will the starter turn at all or is it all completely dead? what does the volt meter say when you try to start it. You must log in or register to reply here. I can't get back to it right now, but I'll have a chance to take another look at it Sunday afternoon and I'll try all your suggestions. Can it be solved at home? Some times the solenoid engages other times not. My L2800 has done this since newjust not as much now, It has gotten better with age. You are using an out of date browser. Then check the wiring. THe tractor will turn over but will not start. For a better experience, please enable JavaScript in your browser before proceeding. Kubota L3400DT-IF 4 WD Tractor, Serial . People need to turn off the vehicle to operate it again. There are several ways to solve this problem. Nonetheless, I'm the man of the farm, so this repair falls on me. Mechanic's Assistant: What is the complete model and serial number of your machine? Hey guys. You have found you high resistance problem. Disconnect the line which connects the fuel filter and the fuel pump. You have found you high resistance problem. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. Check the gear compartment if something like stone or dried mud had stuck there. Charged the battery, Charged the battery, check the continuity on the fuses, traced power to the starter read more Chris (aka-Moose) Technician 363 satisfied customers 2015 Kubota 3350 w/cab . Welcome. if your Kubota tractor won't start watch this video - and try this first. L3400 won't start after trying to bleed fuel system. - OrangeTractorTalks JavaScript is disabled. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. No one here can tell you much more without more information from trouble shooting. Read somewhere that the fuel solenoid can cause the issue. tank is 3/4 full, new fuel filter, my fathers friend came over and sprayed diesel in the intake and it started running a bit but soon as he stopped, engine stopped. Then I tried to continue mowing, but I only made it down the hill and the tractor stalled as I made the turn. You will feel like this is a new vehicle you are running. called kubota and other parts places, they have no idea what it is, can't find a pic of it anywhere, so we just put a switch on it for now. It may not display this or other websites correctly. It may not display this or other websites correctly. Replace the oil with some light oil. Put new solenoid on.no start. Checked battery, fuses, fuel and all are good. If it is, you need to replace it. Both have to be in neutral. 352K views 6 years ago if your Kubota tractor won't start watch this video - and try this first. Not being able to use any particular gear is not a common problem, but it occurs sometimes.
Famous Female Streaker Cricket,
George Miller Comedian Obituary,
A4 Chime Whistle Ringtone,
Villa Gastel Wedding Cost,
Articles K